  asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 866 513 2839 ? 201 6 bel power solutions, inc. bcd.00800_001 the bel power solutions 350invchgt150 - 120 - 240 - 8g is a 15 kw inverter / charger that converts ac to dc voltages in charge m ode and converts dc voltages to pure sine wave ac in standalone or utility mode. in the standalone mode the inverter/charger could suppl y some a c accessories and in the utility mode is able to push energy back to the grid . the liquid cooled inverter / charger operates at 250 - 435 vdc and 120/240 vac (50/60 hz) split - phase. the inverter charger powers up to 15 kw in either direction. feature s include very high efficiency, high reliability, low total harmonic distortion (ac), low output voltage noise (dc), and excellent dynamic response to load/input changes. ? up to 15 k w power in charge , 14.4 k va in standalone and 13.2 k va in utility mode ? 90 % typical efficiency ? charge mode output 250 - 435 vdc ? standalone mode output 120/240 vac - 50/60 hz (split - phase) overload capability 200% of rated power during 10 sec. ? utility mode output 208 vac - 60 hz, ul1741/ieee1547 certified ? j19 39 compliant can control and monitoring ? over - t emperature, output over - voltage and over - current protection s ? sae 1455 complaint environmental standards ? ip65 and ip67 rating ? hybrid electric vehicles , buses, trucks ? storage energy systems
2 tech.support@psbel.com model description 350invchgt150 - 120 - 240 - 8g inverter/ charger 350invchgt150 - con - kit - 8g connector kit with dc mating connector, including hv dc cable ( 3 m ) 350invchgt150 - con - kit - 9g connector kit with dc mating connector, excluding hv dc cable parameter description / condition min nom max unit input voltage nominal operating range absolute operating range 100 90 230 240 264 vac input current charge mode: @ 195 C C parameter description / condition min nom max unit output type dc current source with 120 hz sine wave ripple component output voltage not regulated; depends on battery voltage 250 375 435 vdc output current average output current adjustable via can 40 adc output po wer @ 240 vac / 250 vdc @ 240 vac / >375 vdc 10 15 kw efficiency @ vin = 240 vac, vo = 375 vdc io = 40 adc 88 90 % static regulation charge mode: set point accuracy @ idcset = 30 a, load in voltage mode, tcoolant = 25c thermal drift after 15 min w arm up period - 1 - 0.05 + 1 + 0.05 adc %/c turn - on/off delay charge mode: turn - on delay turn - off delay 3 1 s parameter description / condition min nom max unit input voltage 250 375 435 vdc input current average inpu t current 40 adc input line under - voltage standalone mode: inverter shutdown 240 vdc inrush current external pre - charging circuit is required as part of battery management system. input capacitance 400
3 tech.support@psbel.com parameter description / condition min nom max unit output voltage split - phase 120 / 240 vac 2x 112 2x 120 2x 128 vac output current export mode: phase - l1, l2 neutral - n 60 40 arms output power @ >375 vdc / 240 vac 1 4.4 kva frequency can selectable 50 or 60 hz mode: 50 hz mode: 60 hz 49.9 59.9 50 60 50.1 60.1 hz efficiency @ 250 vdc, 435 vdc, iac1 = iac2 = 60 arms 88 90 % load regulation export mode: @ 250 vdc, 435 vdc - 8 0 + 8 vac load step response load step 3 0 arms iac1 = iac2 minimum iac1 = iac2 = 6 arms voltage deviation response time - 30% 0 + 30% 4 vac ms periodic and random deviation export mode: @ 120 vac / 60 arms - 3.5 + 3.5 vpk total harmonic distortion @ 250, 435 vdc; load 0 C 60 arms 3 % gfci leakage current threshold @ 120 vac, 60 hz reaction time 25 30 30 ma ms turn - on/off delay export mode: turn - on delay turn - off delay 3 1 s parameter description / condition min nom max un it input voltage 250 375 435 vdc input current average input current 40 adc input line under - voltage utility mode: inverter shutdown 240 vdc inrush current external pre - charging circuit is required as part of battery management system. inp ut capacitance 400 parameter description / condition min nom max unit output voltage 183 208 229 vac operating frequency 59.3 60 60.5 hz maximum continuous output power @ >375 vdc / 2 08 vac 13.2 kva effi ciency @ 250 vdc, 435 vdc, iac = 6 3 arms 88 90 % maximum continuous output current @ >375 vdc / 2 08 vac 63 arms maximum output overcurrent protection 100 a maximum output fault current duration 1.73ms, 188 arms duration 50ms 518 19 pka arms n umber of the phases 1 - output power factor rating 1 -
4 tech.support@psbel.com condition simulated utility source maximum time (sec) before cessation of current to the simulated utility vol tage (v) frequency (hz) a < 0.50 vnor rated 0.16 (default) b 0.50 vnor v < 0.88 vnor rated 2 (default) c 1.10 vnor < v < 1.20 vnor rated 1 (default) d 1.20 vnor v rated 0.16 (default) e rated f > 60.5 (default) 0.16 (default) f rated f < 59.3 ( default) 0.16 (default) g reconnect time 300 s (default) field adjustable 10 s to 300 s note: the trip limit & trip time accuracy is +/ - 3 v and +/ - 0.15 hz. parameter description / condition min nom max unit output over - curr ent protection standalone mode: 10s over - load phase - l1, l2 neutral - n 120 60 arms short circuit survival - operating self - protecting; hiccup mode output over - voltage protection charge mode: latch type, can adjustable, max. ov duration 1ms standa lone mode: latch type, max. ov duration 8.33 ms 250 140 435 150 vdc vac output under - voltage protection charge mode: latch type, can adjustable, max. uv duration 1.0 s standalone mode: uv duration 1.0 s 250 85 435 95 vdc vac over - temperature prot ection converter shutdown at t_coolant higher than 65 c input overvoltage protection charge mode: standalone mode: 272 432 288 448 vac vdc parameter description / condition ign (key switch) can communication enable level high = enable control pilot function and levels according to sae j1772 proximity detection function and levels according to sae j1772 led1 pwm current source max 50ma. supplied from battery voltage input (vbat 12v) pwm controlled with can bus. led2 pwm current source max 50ma. supplied from battery voltage input (vbat 12v) pwm controlled with can bus. vbat 12v battery voltage input. used to supply can bus communication evse_wake_out energy taken from vbat. voltage level is approximately 1.5v b elow connected vbat. high side output wake vcu and other vehicle control modules and/or relay coils. wake output goes high when control pilot is active and goes low when can command from vcu is received or in sleep mode. lcd_scl / lcd_sda i 2 c for communi cation with display; 5v logic level; max 100khz gfci_led pwm current source max 50ma for supply of led (gfci status) gfci_rst if signal is pulled up to 12v for >5ms gfci will reset can_baud_rate can bus speed; open C C
5 tech.support@psbel.com parameter description / condition criterion insulation signals to ac signals to dc ac to dc signals rtn to pe basic 2250 vdc basic 2500 vdc reinforced 2500 vdc electrically connected * radiated emission fcc15 class a conducted emission fcc15, cispr 22, en 55022 class a electrostatic discharge iec 61000 - 4 - 2 performance criterion b radiated electromagnetic field iec 61000 - 4 - 3, sae j1113/21 performance criterion b, status 2 electrical fast tra nsient (eft) /burst iec 61000 - 4 - 4; level 2 (+/ - 2 kv, 5 khz) performance criterion b surge immunity iec 61000 - 4 - 5; level 3 surge (+/ - 1 kv dm and +/ - 2 kv cm) performance criterion b rf conducted immunity iec1000 - 4 - 6; level 3 (10v, 0.1580 mhz, am 80%, 1 kh z) performance criterion a flicker tests iec 61000 - 3 - 3 electrical transient conduction along supply lines iso 7637 - 2, iso 16750 - 2 * due to referencing of control pilot and proximity against pe/chassis (sae j1772) parame ter description / condition min nom max unit altitude non - operating:18.6 kpa absolute pressure 12200 m operating temperature liquid cooled: t_coolant t_ambient - 40 - 40 +60 +85 c storage temperature - 40 +95 c humidity sae j1455 shock sa e j1455, gmw - 3172 vibration sae j1455, gmw - 3172 protection ip65 and ip67 (4x) / when all matting connectors are installed 13.1 ac input connector inverter / charger side: mfg: deutsch; pn: hdp24 - 24 - 7pn - c038 mating connector: mfg: deutsch; pn: hdp26 - 24 - 7sn - c038 use copper conductors only with an insulation rating of 120 c. note: follow connector mfg instructions for co rrect connector assembly. pin function wire size deutch matting teminal p/n 1 control - pilot* awg 16 - 20 0462 - 201 - 16141 2 proximity* awg 16 - 20 0462 - 201 - 16141 3 l1 - input awg 4 5962 - 203 - 04141 4 l2 or n - input awg 4 5962 - 203 - 04141 5 not used n/a n/a 6 pe* awg 4 5962 - 203 - 04141 7 not used n/a n/a * functions and levels according sae j1772; insulated from ac side; referenced to 12v_rtn
6 tech.support@psbel.com 13.2 ac output connector inverter / charger side: mfg: deutsch; pn: hdp24 - 24 - 9se mating connector: mfg: deutsch; pn: hdp26 - 24 - 9pe - l015 use copper conductors only with an insulation rating of 120 c. note: follow connector mfg instructions for correct connector assembly. p in function wire size deutch matting teminal p/n r n - output awg 6 0460 - 204 - 0490 s l1 - output awg 8 - 10 0460 - 204 - 08141 t pe* awg 12 - 14 0460 - 204 - 12141 u l2 - output awg 8 - 1 0 0460 - 204 - 08141 v pe* awg 12 - 14 0460 - 204 - 12141 w pe* awg 12 - 14 0460 - 204 - 12141 x pe* awg 12 - 14 0460 - 204 - 12141 y pe* awg 12 - 14 0460 - 204 - 12141 z pe* awg 12 - 14 0460 - 204 - 12141 * all pe terminals (t, v, w, x, y, z) shall be connected together to keep safety rating requirements. 13.3 dc input / output connector inverter / charger side: mfg: te connectivity; pn: 8 - 2141272 - 1 (hva - 630) mating connector: mfg: te connectivity; pn: 2177140 - 2 hv cable: mfg: co ro plast: p n: 9 - 2641 note: hvil_in and hvil_out signals are connected directly to signal 2 connector. signals are insulated from hv dc side. signals are insulated from 12v_rtn up to 60 vdc basic ins ulation. current rating is 2 a. 13.4 signal 1 inverter / charger side: mfg: te connectivity; pn: 776087 - 5 mating connector: mfg: te connectivity; pn: 770680 - 5 pin name function amps per pin 1 lcd scl i 2 c scl for display 2 (awg20) 2 lcd sda i 2 c sda for display 2 (awg20) 3 gfci led gfci status signal 2 (awg20) 4 gfci_rst pin to connect external gfci reset button (button connected to +12v) 2 (awg20) 5 12v_bat connected to connector 2 pin 3 2 (awg20) 6 12v_rtn return for 12v battery and signals connected with connector 2 pin 10 2 (awg20) 7 switch_in loop to connector 2 pin 14 2 (awg20) 8 alarm_out loop from connector 2 pin 13 2 (awg20) 9 ign loop from connector 2 pin 12 2 (awg20) 10 - 23 na hvil_in hvil_out v dc (+) v dc (-) 1 9 16
7 tech.support@psbel.com 13.5 signal 2 inverter / charger side: mfg: te connectiv ity; pn: 776087 - 1 mating connector: mfg: te connectivity; pn: 770680 - 1 pin name function amps per pin 1 led_1 charger status led1 2 (awg20) 2 led_2 charger status led2 2 (awg20) 3 vbat 12v battery voltage input 2 (awg20) 4 canh_1 can bus h 2 (awg20) 5 canl_1 can bus l 2 (awg20) 6 hvil_1 hvil from dc connector (hvil_in) 2 (awg20) 7 hvil_2 hvil from dc connector (hvil_out) 2 (awg20) 8 canh_2 can bus h (connected to pin 4) 2 (awg20) 9 canl_2 can bus l (connected to pin 5) 2 (awg20) 10 12v_rtn retur n for 12v battery and signals 2 (awg20) 11 evse_wake_out signal to wake up vehicle control unit (vcu module) 2 (awg20) 12 ign (key switch) supply of can and bias convertor enable. 2 (awg20) 13 alarm_in loop t o connector 1 pin 8 2 (awg20) 14 switch_out l oop from connector 1 pin 7 2 (awg20) 15 evse_wake_out connected to pin 11 2 (awg20) 16 na 2 (awg20) 17 can_baud_rate open C 500 kbit; grounded C 250 kbit 2 (awg20) 1 8 - 23 na 13.6 signal 3 inverter / charger side: mfg: te connectivity; pn: 776267 - 1 mating connector: mfg: te connectivity; pn: 776273 - 1 pin name function amps per pin 1 canh_3 can bus h (connected to connector signal 2 / pin 4) 2 (awg20) 2 canl_3 can bus l (connected to connector signal 2 / pin 5) 2 (awg20) 3 vbat connected to connector signal 2 / pin 3 2 (awg20) 4 12v_rtn return for 12v battery and signals connected to connector signal 2 / pin 10 2 (awg20) 5 evse_wake_out connected to connector signal 2 / pin 11 2 (awg20) 6 control pilot connec ted to ac input connector / pin 1 2 (awg20) 7 proximity connected to ac input connector / pin 2 2 (awg20) 8 key_switch connected to connector signal 2 / pin 12 2 (awg20) 9 - 14 nc 1 9 16
8 tech.support@psbel.com parameter description / condition cooling type: liquid cooling coolant medium/mixture: 50/50 glycol/water coolant flow: min.11.4 lpm max. coolant pressure: 15 psi max. pressure drop: 3 psi inlet/outlet coolant connection: sae fittings with outer thread 1 - 14uns for i nternal hose size >=5/8 (e.g. parker p/n: 10f5omloss) material of fittings: stainless steel fittings provided with inverter charger: 2pcs parker p/n: 10f5omloss or equivalent parameter conditions / description dimensions (w x h x d) 605 x 1 7 0 x 3 9 4 mm weight 38.5 kg enclosure material aluminum alloy figure 1 . mechanical dimensions C front view
9 tech.support@psbel.com figure 2. mechanical dimensions C side view figure 3 . mechanical dimensions C top view nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may chan ge depending on the date manufactured. specifications are subject to change without notice. 360 0.5 18 3 9 4 1 . 2 o 9 +0.5 0 6x product label warning labels 20 2 0 4 0 55


▲Up To Search▲   

 
Price & Availability of 350INVCHGT150-120-240-8G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X